Follow Me

Product Data Sheet - AcryShield® A420

describe the image Download PDF Version

1. PRODUCT NAME

ACRYSHIELD® A420
Elastomeric Roof Coating

2. MANUFACTURER

NATIONAL COATINGS CORPORATION

1201 Calle Suerte Camarillo, CA 93012

Phone: 800-423-9557
FAX: 800-294-3866
www.nationalcoatings.com

3. PRODUCT DESCRIPTION

ACRYSHIELD A420 is a multi-purpose, acrylic, elastomeric coating for use over a variety of substrates including asphalt and metal roofing. A420 has unique “bleed blocking” properties that make it particularly suited for coating over asphalt surfaces. A420 far exceeds the ASTM D6083 requirements for critical properties such as tensile strength, elongation, wet adhesion and weatherability.

BENEFITS: APPROVALS:
  • Seamless Waterproofing
  • Fully-Adhered Installation
  • Asphalt Bleed Blocking
  • acrylic Durability
  • Energy Savings
  • Prolonged Roof Life
  • Reduced Life Cycle Costs
  • Renewable
  • Ultra Low VOC

As an ENERGY STAR® Partner -Product in white, meets the ENERGY STAR® guidelines for energy efficiency.

EnergyStarLogo

UL 790 Class A Rating

describe the image

ICC-ES Evaluation Report #5007

describe the image

California State Fire Marshall

describe the image

CRRC Rated

describe the image

California Title 24 Compliant

Title 24

Florida Power and Light

describe the image

4. TECHNICAL DATA

See Table on reverse side.

5. INSTALLATION

  • May be applied by spray, brush, or roller.

  • All surfaces must be clean, dry, and free of dirt, grease, oil, or other contaminants that would interfere with proper adhesion.

  • Apply at temperatures above 50ºF.

  • Apply only when weather conditions will permit drying before rain, dew or freezing temperatures.

  • Cool temperatures and high humidity retard cure.

  • Yield=7.2 DFT/gallon.

  • For application details see specific Guide Specifications.

6. AVAILABILITY AND COST

AcryShield A420 may be purchased directly from National Coatings Corporation. For information call 800-423-9557.

7. WARRANTY

Various warranties are available for specific ACRYSHIELD RESTORATION SYSTEMS and ACRYPLY® ROOFING SYSTEMS installed by approved applicators. Periodic maintenance of ACRYSHIELD RESTORATION SYSTEMS and ACRYPLY ROOFING SYSTEMS ensures extended performance and reduces life cycle costs.

8. MAINTENANCE

Periodic maintenance of ACRYSHIELD RESTORATION SYSTEMS and ACRYPLY ROOFING SYSTEMS ensures extended performance and reduces life cycle costs.

9. TECHNICAL SERVICES

Additional information, product brochures, and guide specifications are available. Roof energy evaluations, life cycle cost analyses, and other roof management services are also available from a National Coatings Technical Consultant.

10. FILING SERVICES

Additional product information is available from National Coatings Corporation.

ACRYSHIELD® A420

ASTM D6083 Technical Data
Property
Requirement
Result
Initial Tensile Strength (psi) 200 Minimum > 250
Initial Elongation (%) 100 Minimum > 250
Dry Adhesion (pli)* No Reference > 6.0
Wet Adhesion (pli)* 2 Minimum > 4.5
Tear Resistance (lbf / in) > 60 >100
1000-hr Accelerated Weathering No Cracking or Checking No Cracking or Checking
Elongation After Accelerated Weathering (%) 100 Minimum > 200
Permeance (perms) 50 Maximum < 15
Fungi Resistance (Zero = No Growth) Zero Rating Zero Rating
Volume Solids (%) > 50 45 ± 2
Weight Solids (%) > 60 60 ± 2
Viscosity (KU) 85-141 110 ± 10
*Measured Over Aged PVC Substrate

 

Cool Roof Data

(Product tested in white color)
Property
Method
Result
Initial Solar Reflectance ASTM C1549 .83
Thermal Emittance ASTM E408 .94


ACRYSHIELD A420 is for industrial/commercial applications only. These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use are beyond our control.